Page 50 - Products Catalogue 2019_Pedestrian EN 01-2019
P. 50
STANDARD TECHNICAL OPTIONS
CHARACTERISTICS (PER LANE)
1. EGRESS operating mode: obstacles open in the direction of
Electrical supply Single phase 110-240 VAC (+/-10%) - 5A - egress by a simple push
50/60Hz + ground
2. Battery backup for automatic opening in case of power
Power Standby: 50w failure and obstacles locking mechanism in egress direction
consumption Cycle: 170w
Maximum: 300w 3. Clear 10mm thick tempered glass side panels
4. Mobile leaf height: 1200, 1500 or 1700mm
Motors (x2) 24 VDC – nominal output power 93w 5. Enhanced electronic protection and ‘trolley’ protection cells
Passageway (L) 600mm kit (A and B directions)
550mm < L < 725mm (min/max) 6. Transparent glass side wall with enhanced electronic
Min opening or closing 0,7 s protection and ‘trolley’ protection cells kit (A and B
times (Depending on the access control system directions)
reactivity and the speed of users) 7. Reader post
8. Standard support bracket for external reader integration
Ambient operating from 0 to +50°C 9. Customised self-adhesive logo on obstacles
Temperature 10. Black handrail cover
11. Fixing frame to embed in the concrete to fix the equipment
Ambient relative < 95%, no condensation and pass the electric cables
humidity in operation 12. Monitoring panel
13. Connectivity kit for Ethernet connection of one or more
MCBF 5,000,000 mean cycles between failures, lanes to the network
with recommended maintenance.
Note: For restrictions on options refer to the price list.
Sound level 55 dB
Weight 62kg (per left/right unit)
91kg (per intermediate unit)
IP 40
Conforms to European standards
PRECAUTIONS FOR USE
77For security reasons, children (user smaller than 1m tall for
mobile obstacles of 900mm height and smaller than 1.3m for
mobile obstacles from 1200mm to 1700mm height) must be
supervised by an adult at all times when in the vicinity of the
unit and during passage through the lane
77A child must precede the accompanying adult when lane
passage is required
77If habitual use by children is anticipated, Automatic Systems
recommends the addition of all options required to optimize
the level of protection
WORK TO BE PROVIDED
BY THE CUSTOMER
77Bolting the unit to the floor
77Power supply
77Cabling between gates in the same array
77Cabling to any external peripherals
77Integration of any accessories
Note: Comply with the installation drawing.
With a constant view to adopting the latest technological developments, Automatic Systems reserves the right to amend the above information at any time.
Products Catalogue | Pedestrian | 50