Page 54 - Products Catalogue 2019_Pedestrian EN 01-2019
P. 54

STANDARD TECHNICAL                                                        OPTIONS
CHARACTERISTICS (PER LANE)
                                                                          1.	EGRESS operating mode: obstacles open in the direction of
Electrical supply           Single phase 110-240 VAC (+/-10%) - 5A -         egress by a simple push
                            50/60Hz + ground
Power consumption                                                         2.	Battery backup for automatic opening in case of power failure
                            Standbay :            50w                        and obstacles locking mechanism in egress direction
Motors (x2)                 Cycle :               170w
Passageway (L)              Maximum :             300w                    3.	Clear 10mm thick tempered glass side panels
                                                                          4.	Mobile leaf height: 1200, 1500 or 1700mm
Min opening or closing      24 VDC – nominal output power 93w             5.	Enhanced electronic protection and ‘trolley’ protection cells
times
                            900mm                                            kit (A and B directions)
Ambient operating           725mm < L < 950mm (min/max)                   6.	Transparent glass side wall with enhanced electronic
Temperature
Ambient relative humi-      0,9 s                                            protection and ‘trolley’ protection cells kit (A and B directions)
dity in operation           (Depending on the access control system       7.	Reader post
MCBF                        reactivity and the speed of users)            8.	Standard support bracket for external reader integration
                                                                          9.	Customised self-adhesive logo on obstacles
Sound level                 from 0 to +50°C                               10.	Black handrail cover
Weight                                                                    11.	Fixing frame to embed in the concrete, to fix the equipment
                            < 95%, no condensation
IP                                                                             and pass the electric cables
                            5,000,000 mean cycles between failures, with  12.	Monitoring panel
                            recommended maintenance*.                     13.	Connectivity kit for Ethernet connection of one or more

                            55 dB                                              lanes to the network

                            64kg (per left/right unit)                    Note: For restrictions on options refer to the price list.
                            95kg (per intermediate unit)
                                                                          WORK TO BE PROVIDED
                            40                                            BY THE CUSTOMER

                            Conforms to European standards                77Bolting the unit to the floor
                                                                          77Power supply
* Maintenance operations are detailed in the technical manuals.           77Cabling between gates in the same array
                                                                          77Cabling to any external peripherals
PRECAUTIONS FOR USE                                                       77Integration of any accessories

77For security reasons, children (user smaller than 1m tall for           Note: Comply with the installation drawing.
  mobile obstacles of 900mm height and smaller than 1.3m for
  mobile obstacles from 1200mm to 1700mm height) must be
  supervised by an adult at all times when in the vicinity of the
  unit and during passage through the lane

77A child must precede the accompanying adult when lane
  passage is required

77If habitual use by children is anticipated, Automatic Systems
  recommends the addition of all options required to optimize
  the level of protection

STANDARD DIMENSIONS (MM)

                            200 600         2150  900           200       1555
                                          250

                                                                                                                                                                                 2000
                                                                                                                                                          850 1150

1700                                                                 991
      1500
            1200
                  900

                            270 50                420 50

                       160

                            SlimLane 940          SlimLane 950            820 820                 65
                                                                                          1640  157.5

With a constant view to adopting the latest technological developments, Automatic Systems reserves the right to amend the above information at any time.

Products Catalogue | Pedestrian | 54
   49   50   51   52   53   54   55   56   57   58   59