Page 58 - Products Catalogue 2019_Pedestrian EN 01-2019
P. 58
STANDARD TECHNICAL OPTIONS
CHARACTERISTICS (PER LANE)
1. EGRESS operating mode: obstacles open in the direction of
Electrical supply Single phase 110-240 VAC (+/-10%) - 5A - egress by a simple push
50/60Hz + ground
Power consumption 2. Battery backup for automatic opening in case of power failure
Standbay: : 50w and obstacles locking mechanism in egress direction
Motors (x2) Cycle : 170w
Passageway (L) Maximum : 300w 3. Clear 10mm thick tempered glass side panels
4. Enhanced electronic protection and ‘trolley’ protection cells
Min opening or closing 24 VDC – nominal output power 93w
times kit (A and B directions)
1200mm 5. Transparent glass side wall with enhanced electronic
Ambient operating 950mm < L < 1200mm (min/max)
Temperature protection and ‘trolley’ protection cells kit (A and B directions)
Ambient relative humi- 1,19 s 6. Reader post
dity in operation (Depending on the access control system 7. Standard support bracket for external reader integration
MCBF reactivity and the speed of users) 8. Customised self-adhesive logo on obstacles
9. Black handrail cover
Sound level from 0 to +50°C 10. Fixing frame to embed in the concrete, to fix the equipment
Weight
< 95%, no condensation and pass the electric cables
IP 11. Monitoring panel
5,000,000 mean cycles between failures, with 12. Connectivity kit for Ethernet connection of one or more
recommended maintenance*.
lanes to the network
55 dB
Note: For restrictions on options, refer to the price list.
64kg (per left/right unit)
95kg (per intermediate unit) WORK TO BE PROVIDED
BY THE CUSTOMER
40
77Bolting the unit to the floor
Conforms to European standards 77Power supply
77Cabling between gates in the same array
* Maintenance operations are detailed in the technical manuals. 77Cabling to any external peripherals
77Integration of any accessories
PRECAUTIONS FOR USE
Note: Comply with the installation drawing.
77For security reasons, children (user smaller than 1m tall for
mobile obstacles of 900mm height and smaller than 1.3m for
mobile obstacles from 1200mm to 1700mm height) must be
supervised by an adult at all times when in the vicinity of the
unit and during passage through the lane
77A child must precede the accompanying adult when lane
passage is required
77If habitual use by children is anticipated, Automatic Systems
recommends the addition of all options required to optimize
the level of protection
STANDARD DIMENSIONS (MM)
1450
1600 1555
200 1200 200
900
160
991
1490
570 50
820 820 65
1640 157.5
With a constant view to adopting the latest technological developments, Automatic Systems reserves the right to amend the above information at any time.