Page 72 - Products Catalogue 2019_Pedestrian EN 01-2019
P. 72
STANDARD TECHNICAL OPTIONAL
CHARACTERISTICS
1. Non standard height of glass leaves: 1000, 1200 or 1900mm
Electrical supply Single-phase 230 VAC + ground, 50/60Hz. and fixed leaves with equivalent height
(do not connect to a floating network or to
Motor high impedance earthed industrial distribution 2. Protective section on mobile glass leaves, for heights 1000,
Nominal consumption network) 1200, 1900mm
Ambient T° of operation
Net weight of a gate Three-phase asynchronous 0.12kW 3. Group of protection cells on fixed glass leaves
Min opening or closing 4. Enhanced electronic protection cell kit (both directions)
times 250W / per gate. 5. Trolley protection cell kit
6. Enhanced electronic protection and trolley protection cell kit
MCBF from 0 to +50°C 7. Free opening’ cell kit (wheelchair detection)
8. Function pictogram
IP depending on its configuration (left, right, inter- 9. External support kit for reader integration
Communication mediate): between 160 and 250kg. 10. Electro-magnets for obstacles locking in open position in
Opening time : 0.3s case of power failure
Closing time : 0.5s 11. Power supply 120 VAC-60Hz
(minimum movement times, configurable. These 12. Personalised logo on fixed or mobile leaf (sticker like sand
times do not take into account the reaction
of the access control system. The passage blasting)
request memory function makes it possible 13. Painted stainless steel panels (RAL colours)
to accelerate the flow: no closing between 14. Filled extension (stainless steel doors)
2 requests) 15. Wooden top cover (laminated beech)
16. Stainless steel top cover
(average number of cycles between 17. Smart ‘n Slim: IP interface
breakdowns), when respecting recommended
maintenance: 5.000.000. Note: For restrictions on options, refer to the price list.
40 WORK TO BE PROVIDED
BY THE CUSTOMER
CAN bus communication between the various
modules making up the passage. 77Bolting the unit to the floor
77Power supply
Conforms to CE standards. 77Cabling between gates in the same array
The Silicon protection strip on mobile leaf 77Cabling to any external peripherals
option is necessary to comply with the norms 77Integration of any accessories
related to impact force
Note: Comply with the installation drawing.
PRECAUTIONS FOR USE
77For security reasons, children (user smaller than 1m tall for
77mobile obstacles of 900mm height and smaller than 1.3m for
mobile obstacles from 1200mm to 1700mm height) must be
supervised by an adult at all times when in the vicinity of the
unit and during passage through the lane
77A child must precede the accompanying adult when lane
passage is required
77If habitual use by children is anticipated, Automatic Systems
recommends the addition of all options required to optimize
the level of protection
STLeAftNDARD DInItMermEedNiaSte IONS (MMRig)ht
(SggLLaae9ttf0ete1) Intergm(SagLtaee9td0ei1a) te Rgiag(StghLeat9t0e1)
(SL 901) (SL 901) (SL 901)
1600
1600
1700
1700
1020 243
1020 243
150170 300
115 150 170 300
115 300 600 300 600
300 600 300 600
(2100(2) 100)
With a constant view to adopting the latest technological developments, Automatic Systems reserves the right to amend the above information at any time.
Products Catalogue | Pedestrian | 72