Page 72 - Products Catalogue 2019_Pedestrian EN 01-2019
P. 72

STANDARD TECHNICAL                                                                 OPTIONAL
CHARACTERISTICS
                                                                                   1.	Non standard height of glass leaves: 1000, 1200 or 1900mm
Electrical supply        Single-phase 230 VAC + ground, 50/60Hz.                      and fixed leaves with equivalent height
                         (do not connect to a floating network or to
Motor                    high impedance earthed industrial distribution            2.	Protective section on mobile glass leaves, for heights 1000,
Nominal consumption      network)                                                     1200, 1900mm
Ambient T° of operation
Net weight of a gate     Three-phase asynchronous 0.12kW                           3.	Group of protection cells on fixed glass leaves
Min opening or closing                                                             4.	Enhanced electronic protection cell kit (both directions)
times                    250W / per gate.                                          5.	Trolley protection cell kit
                                                                                   6.	Enhanced electronic protection and trolley protection cell kit
MCBF                     from 0 to +50°C                                           7.	Free opening’ cell kit (wheelchair detection)
                                                                                   8.	Function pictogram
IP                       depending on its configuration (left, right, inter-       9.	External support kit for reader integration
Communication            mediate): between 160 and 250kg.                          10.	Electro-magnets for obstacles locking in open position in

                         Opening time : 0.3s                                            case of power failure
                         Closing time : 0.5s                                       11.	Power supply 120 VAC-60Hz
                         (minimum movement times, configurable. These              12.	Personalised logo on fixed or mobile leaf (sticker like sand
                         times do not take into account the reaction
                         of the access control system. The passage                      blasting)
                         request memory function makes it possible                 13.	Painted stainless steel panels (RAL colours)
                         to accelerate the flow: no closing between                14.	Filled extension (stainless steel doors)
                         2 requests)                                               15.	Wooden top cover (laminated beech)
                                                                                   16.	Stainless steel top cover
                         (average number of cycles between                         17.	Smart ‘n Slim: IP interface
                         breakdowns), when respecting recommended
                         maintenance: 5.000.000.                                   Note: For restrictions on options, refer to the price list.

                         40                                                        WORK TO BE PROVIDED
                                                                                   BY THE CUSTOMER
                         CAN bus communication between the various
                         modules making up the passage.                            77Bolting the unit to the floor
                                                                                   77Power supply
                         Conforms to CE standards.                                 77Cabling between gates in the same array
                         The Silicon protection strip on mobile leaf               77Cabling to any external peripherals
                         option is necessary to comply with the norms              77Integration of any accessories
                         related to impact force
                                                                                   Note: Comply with the installation drawing.
PRECAUTIONS FOR USE

77For security reasons, children (user smaller than 1m tall for
77mobile obstacles of 900mm height and smaller than 1.3m for

  mobile obstacles from 1200mm to 1700mm height) must be
  supervised by an adult at all times when in the vicinity of the
  unit and during passage through the lane
77A child must precede the accompanying adult when lane
  passage is required
77If habitual use by children is anticipated, Automatic Systems
  recommends the addition of all options required to optimize
  the level of protection

STLeAftNDARD DInItMermEedNiaSte IONS (MMRig)ht

(SggLLaae9ttf0ete1)  Intergm(SagLtaee9td0ei1a) te  Rgiag(StghLeat9t0e1)

(SL 901)                 (SL 901)                  (SL 901)

                                                                                                                                                                        1600
                                                                                                                                                                                1600

                                                                         1700
                                                                             1700

                                                                         1020             243
                                                                            1020   243

                                                                                                                          150170                                               300
                115 150              170                                                                                                                                300
               115 300 600 300 600

                                                                                                                           300 600 300 600
                                                                                                                                                         (2100(2) 100)

With a constant view to adopting the latest technological developments, Automatic Systems reserves the right to amend the above information at any time.

Products Catalogue | Pedestrian | 72