STANDARD TECHNICAL                                                                OPTIONS
SPECIFICATIONS
                                                                                  1.	Lock for emergency crank entry
Power supply                    Single phase 230 VAC, 50/60Hz* + ground.          2.	Command by push button(s) box
                                (not to be connected to a floating network or to  3.	Command by key switch on housing
Nominal power                   high impedance earthed industrial distribution    4.	Command by radio transmitter/receiver
consumption                     network)                                          5.	Inductive loops for car or trucks detection
Motor                           420W                                              6.	Loops detector
Gearbox                                                                           7.	Photo electric cells (automatic opening, closing after passage, safety)
Thermostatic heater             induction, 3-phase 250W                           8.	Cell fixed on housing or on post
Ambient operation               worm-screw, life-lubricated.                      9.	Input/Output/CAN extension board
temperature                     80W                                               10.	Totaling counter (without or with reset button)
Boom arm balancing              from -35 to +50°C.                                11.	LED traffic light alone or on a post fixed to housing
Useful length of boom                                                             12.	Support post for traffic lights
arm (L)                         by adjustable spring(s).                          13.	Connection board for not Automatic Systems’ traffic light
Operation time                  5.50m                                             14.	Non-standard colour RAL paint for housing only (to be
Net weight (housing)
Net weight (arm + skirt)        12 sec.                                                defined at the order)
Protection index                ± 360kg                                           15.	Treatment for aggressive saline environment
Limit switch sensor             15 + 52kg                                         16.	Steel raising base
                                IP44.                                             17.	120VAC – 60Hz power supply
                                IP65.                                             Note: for restrictions on the options, consult the rate table.
                                EC norms compliant.
                                                                                  WORK TO BE SUPPLIED
* To precise when ordering.                                                       BY THE CUSTOMER

STANDARD DIMENSIONS (MM)                                                          77Power supply
                                                                                  77Electrical wiring connection to the control instruments
                                BLG 76L  BLG 76H                                  77Means of fixing to the ground, according to the nature of the

L                               4776     4186                                       existing ground

A                               5500     5000                                     Note: comply with the installation drawing.

B                               1700     1700                                                   B 500*

C                               5315     4815                                                                                                      * Only with BLG 76H

D                               6794     6294

E                               1900     1810

F 200 110

G 606 1016

                                                                                                                                                                        837C
                                                                                                                                                              D
                                         L 540 160

                          500*                                                                                                                                               994

                                                                                                                                                  6001190                       E 500*

                              350 900 G                                           60
                                                            A
                                                                                                                                                                 F