Page 71 - Vehicle Products Catalogue EN 012019
P. 71
STANDARD TECHNICAL OPTIONS
SPECIFICATIONS
1. Climb-proof section on folding fence (crest)
Electrical power supply Single-phase 230 VAC - 50/60Hz + ground (not 2. Extension of the fence over the barrier housing
to be connected to an isolated ground network 3. Automatic opening of the arm during power cuts
or a high impedance earthed industrial network) 4. Locking of the arm in opened and/or closed position. The
Consumption 450W reaction in case of power cut (locked or not) must be specified
when ordering
Motor Three-phased asynchronous 250W 5. Double limit switches for information on BL status in the event of
power failure
Reversible ring and pinion speed reducer, service factor 1.2 6. Tip support: fixed height tip, adjustable tip, electro-magnetic tip,
anti-vandalism tip, anti-vandalism + electro-magnetic tip and
Useful arm length (L) 3 to 7m, in increments of 0.5m electrically lockable tip
7. Support leg for fence and aluminium skirt (if no tip support)
Operation not hampered by 120km/h winds 8. Hood and door intrusion information (by dry contact)
9. Push-button box
Ambient operating Between -20 and +50°C (without optional 10. Fireman emergency opening - anti-vandalism
temperature heating) 11. Programmable clock (weekly or yearly)
12. Lockable switch on housing
Tolerated relative 95% without condensation 13. Radio transmitter/receiver
humidity 14. Detection loop
15. Presence detector for inductive loops
Minimum opening/ 3.5s (adjustable through the control board) 16. Photoelectric cell for opening, closing or automatically stopping
closing time
the barrier arm
Net weight (without arm) 250kg 17. Cell support post
18. Fixating of the cell
MCBF (Mean Cycle in compliance with recommended maintenance: 19. Electronic board for input/output CAN
Between Failure) 3,000,000 cycles 20. Totaling counter with reset button
21. Leds on arm
IP 44 22. Traffic lights (Leds) - alone or fixed on barrier
23. Support post for traffic lights
EC compliant 24. AS1049 card for third-party traffic signs
25. Acoustic alarm 100 dB (±5) - fixed inside
SURFACE TREATMENTS 26. Aluminium STOP sign with a diameter of 300mm
27. LED flashing light on cover for arm movement signalisation
77Zinc-coated internal mechanical parts 28. Anti-vandalism belt, preventing the opening of doors and hood
77Complete body (housing, base plate, cover and doors): zinc 29. Paint of another RAL colour
30. Treatment for aggressive saline environment (recommended
dusting + epoxy structured paint
77Total thickness of the surface treatment exceeds 160 μm when the barrier is installed within 10km of the coast and may be
subject to salt attack): sandblasting + Alu Zinc plating 80μm outside
WORK TO BE SUPPLIED
BY THE CUSTOMER (40μm inside) + polyzinc 80μm + 80μm powder paint
31. Raised base
77Ground installation 32. 120 VAC - 60 Hz power supply
77Power supply 33. Thermostatic 250 or 500W heating for operation to -25 or -45°C
77Wiring to any external devices
Note : for restrictions on the options, consult the rate table.
Note: comply with the installation plan (CH6943-GB).
STANDARD DIMENSIONS (MM)
3000 - 7000 (L)
270,5 225 223,5
= 498 =
450
= 498 =
= 651 =
98
948
1224,5
1798
L + 200 mm
With a constant view of adopting the latest technological developments, Automatic Systems reserves the right to amend the information above, at any time.