Page 87 - Vehicle Products Catalogue EN 012019
P. 87
STANDARD TECHNICAL OPTIONS
SPECIFICATIONS
1. Locking the arm in opened and/or closed position. The reaction
Electrical power supply Single-phase 230 VAC - 50/60Hz + ground in case of power cut (locked or not) must be specified when
(not to be connected to a floating network or ordering
to an industrial distribution network with a high
impedance earth) 2. Double limit switches for information on the arm status in the
event of power failure
Consumption 450W
3. Tip support: fixed height tip, adjustable tip, electro-magnetic tip,
Motor Three-phased asynchronous 250W anti-vandalism tip, anti-vandalism + electro-magnetic tip, folding
tip and electrically lockable tip
Reversible ring and pinion speed reducer, service factor 1.2
4. Rotating base with breaker pin in case of impact and report of
Useful arm length (L) 2 to 4m; in increments of 0.5m housing position by dry contact
Operation not hampered by 120km/h winds 5. Anti-vandalism belt, protection of the doors and hood
6. Bolt cover - to protect arm from vandalism
Ambient operating Between -20 and +50°C (without optional 7. Hood and door intrusion information (by dry contact)
temperature heating) 8. Push-button box
9. Fireman emergency opening - anti-vandalism
Tolerated relative 95% without condensation 10. Programmable clock (weekly or yearly)
humidity 11. Lockable switch on housing
12. Radio transmitter/receiver
Minimum opening/ 2s (adjustable through the control board) 13. Detection loop
closing time 14. Presence detector for inductive loops
15. Photoelectric cell for opening, closing or automatically stopping
Net weight 250kg
(without arm) the barrier arm
16. Cell support post
MCBF (Mean Cycle In compliance with recommended 17. Fixating of the cell
Between Failure) maintenance: 3,000,000 cycles 18. Ultrasonic detector in housing
19. Electronic board for input/output CAN
IP 44 20. Totaling counter with reset button
21. LEDs on arm
EC compliant 22. Traffic lights (Leds) - alone or fixed on barrier
23. Support post for traffic lights
SURFACE TREATMENTS 24. AS1049 card for third-party traffic signs
25. Acoustic alarm 100 dB (±5) - fixed inside
77Zinc-coated internal mechanical parts 26. Aluminium traffic sign (Ø 300mm)
77Complete body (housing, base plate, cover and doors): zinc 27. LED flashing light on cover for arm movement signalisation
28. Anti vandalism LEDs on hood
dusting + epoxy structured 29. Non standard RAL colour
Total thickness of the surface treatment exceeds 160 μm 30. Treatment for aggressive saline environment (recommended
WORK TO BE PROVIDED when the barrier is installed within 10km of the coast and may be
BY THE CUSTOMER subject to salt attack): sandblasting + Alu Zinc plating 80μm outside
(40μm inside) + polyzinc 80μm + 80μm powder paint)
77Adapted ground fastening 31. Raised base
77Power supply 32. 120 VAC - 60 Hz power supply
77Wiring towards eventual external peripherals 33. Thermostatic 250 or 500W heating for operation to -25 or
-45°C
Note: comply with the installation plan (CH6943-GB)
Note : for restrictions on the options, consult the rate table
STANDARD DIMENSIONS (MM)
2000 - 4000 (L)
= 498 = = 498 =
= 741 =
948
1224,5
L + 245
With a constant view of adopting the latest technological developments, Automatic Systems reserves the right to amend the information above, at any time.
87 | Products Catalogue | Vehicle