Page 90 - Vehicle Products Catalogue EN 012019
P. 90

STANDARD TECHNICAL                                                       OPTIONAL
SPECIFICATIONS
                                                                         1.	Back oval arm swing-off - Arm swing-off detection device
Electrical power supply  Single-phase 230 VAC - 50/60Hz + ground.           included
                         (not to be connected to an isolated ground
                         network or a high impedance earthed industrial  2.	Front oval arm swing-off - Arm swing-off detection device
                         network)                                           included

Consumption              During motion: 150W max.                        3.	Carbon Protecta® arm
                         At rest: 44W (Depending of options)             4.	Polystyrene protection for aluminium arm
                                                                         5.	Electro-mechanical holding arm position in case of power
Motor                    Three-phased 230V/90W
                                                                            failure (SR)
Free passage (L)         2 à 4m, increments of 0.5m                      6.	Hood & door intrusion information. (dry contact)
                                                                         7.	Push button box - 2 buttons (opening / closing)
Opening time             Adjustable between 1,2 et 3s (Allowing the      8.	Push button box - 2 push buttons + 1 switch (3 positions)
                         passage of 1500 vehicles/h)                     9.	3 positions switch mounting inside the housing
                                                                         10.	Key switch on housing - automatic / locked open / locked
Operating temperature Between -20 and +60°C
                                                                              closed
Relative humidity        95% max, without condensation                   11.	Inductive loop for vehicles detection
                                                                         12.	Presence detector for inductive loop
MCBF                     Mean cycles between failures - 5.000.000,       13.	Photo-electric cell for safety closing
                         when respecting recommended maintenance         14.	Cell support post for 1 cell
                                                                         15.	Mounting of the cell on the barrier
Weight                   50kg (without arm)                              16.	Ultrasonic detector under arm - protective cover included
                         Arm: 1.6 to 3.2Kg max                           17.	Electronic board for input / output + DP connector
                                                                         18.	Totaling counter (without or with resetting)
IP 55                                                                    19.	Operation pictogram - inside the hood. (red, green &

Conforms to European standards.                                               orange)
                                                                         20.	LEDs on arm
STANDARD RAL COLOURS                                                     21.	LED traffic lights only - Red/green (Ø100 or Ø200mm)
                                                                         22.	Supporting post for traffic lights
RAL 2000 (*)       RAL 3020      RAL 7016            RAL 9010            23.	LED traffic lights (Ø 200) - red/green + acoustic and visual
   Orange
                   Traffic red Anthracite grey Traffic white                    alarm - fixed on barrier
                                                                         24.	Aluminium composite traffic sign (Ø 300)
(*) Standard colour                                                      25.	Non standard RAL colour
All other colours must be specified when ordering                         26.	Customer logo
                                                                         27.	Raised base
Note : These RAL references are available for free.                      28.	Power supply 120V 50/60 Hz
                                                                         29.	Thermostatic heating - Heating for operation until -45° C
WORK TO BE PROVIDED
BY THE CUSTOMER                                                          STANDARD DIMENSIONS (MM)

Note: respect the installation drawing.                                                                2000 - 4000 (L)

77Adapted ground fastening
77Power supply
77Wiring towards eventual external peripherals

                                                                         925
                                                                             1066

                                                                                                                                                                                                                                               Ø 385261