Page 94 - Vehicle Products Catalogue EN 012019
P. 94
STANDARD TECHNICAL OPTIONS
SPECIFICATIONS
1. Protecta® arm in carbon fibre (polyurethane sheath and
Electrical Power supply Single phase 230VAC, 50/60Hz + ground (not sleeve in marine-variety fibre fabric) (*)
to be connected to a floating network or to
high impedance earthed industrial distribution 2. Automatic re-hinging device with Protecta® arm (*)
network) 3. Protection switches in case of door and cover opening
4. Push button(s) box
Nominal power 335W (at maximum speed and without options) 5. Key switch on housing
consumption 6. Inductive loops for cars or trucks detection
7. Presence detector for inductive loops
Motor Three-phase asynchronous 250W motor 8. Photo electric cell (reopening of the arm)
9. Support post for photoelectric cell
Gearbox Life-lubricated worm-screw speed reduction unit 10. Cell fixed on housing
11. Ultrasonic detector under arm (protective cover included)
Type of arm Aluminium tube boom arm, with oval section of 12. Totaling counter (with or without reset)
80 x 53mm 13. Electronic board for Input/Output extension (CAN)
14. Traffic lights (LED) fixed on a post on housing
Minimum operation from 0.6 to 1.7s 15. Traffic lights (LED)
time 16. Support post for traffic lights
17. Electronic board for third-party traffic lights control
Operational between -20 and +50°C (without optional 18. Non standard RAL colour
temperature heating) 19. Treatment for aggresive saline environment
20. Raised steel base
Free passage (L) From 2.5 to 4m 21. 120 VAC, 60 Hz power supply (reduces performances)
22. Heating resistance 80W, for operation down to -35°C
MCBF (mean cycles 10,000,000, with normal maintenance
between failures) (*) Until 3,0 metres, maximum
Up to 20,000 movements per day. STANDARD DIMENSIONS (MM)
Net weight 83kg (excluding arm) L
IP 44
Noise emitted during <70db(A) (measured at 1m from the surface of
operation the machinery and at a height of 1.60m above
the ground; according to ISO3744. No hearing
protection needed.)
Conform to norms.
WORKS TO BE SUPPLIED
BY THE CUSTOMER
77Ground installation
77Power supply
77Wiring to any external devices
Note: comply with the installation plan.
443 400
335 104
1052
872
832
403
335
With a constant view of adopting the latest technological developments, Automatic Systems reserves the right to amend the information above, at any time.
Products Catalogue | Vehicle | 94