STANDARD TECHNICAL OPTIONS
SPECIFICATIONS
1. Rigid aluminium skirt
Electrical power supply Single-phase 230 VAC - 50/60Hz + ground 2. Arm offset on right-hand or left-hand side
(not to be connected to a floating network or 3. Automatic opening of the arm in case of power failure
to an industrial distribution network with a high 4. Locking the arm in opened and/or closed position.
impedance earth)
The reaction in case of power cut (locked or not) must be
Consumption 450W specified when ordering
5. Double limit switches for information on the arm status in the
Motor Three-phased asynchronous 250W event of power failure
6. Tip support: fixed height tip, adjustable tip, electro-magnetic tip,
Reversible ring and pinion speed reducer, service factor 1.2 anti-vandalism tip, anti-vandalism + electro-magnetic tip, folding
tip and electrically lockable tip
Useful arm length (L) 2 to 6m; in increments of 0.5m 7. Rotating base with breaker pin in case of impact and report of
housing position by dry contact
Operation not hampered by 120km/h winds 8. Anti-vandalism belt, protection of the doors and hood
9. Bolt cover - to protect arm from vandalism
Ambient operating Between -20 and +50°C (without optional 10. Hood and door intrusion information (by dry contact)
temperature heating) 11. Push-button box
12. Fireman emergency opening - anti-vandalism
Tolerated relative 95% without condensation 13. Programmable clock (weekly or yearly)
humidity 14. Lockable switch on housing
15. Radio transmitter/receiver
Minimum opening/ 3.5 s (adjustable through the control board) 16. Detection loop
closing time 17. Presence detector for inductive loops
18. Photoelectric cell for opening, closing or automatically stopping
Net weight (without arm) 250kg
the barrier arm
MCBF (Mean Cycle In compliance with recommended 19. Cell support post
Between Failure) maintenance: 3,000,000 cycles 20. Fixating of the cell
21. Ultrasonic detector in housing
IP 44 22. Electronic board for input/output CAN
23. Totaling counter with reset button
EC compliant 24. LEDs on arm
25. Traffic lights (Leds) - alone or fixed on barrier
SURFACE TREATMENTS 26. Support post for traffic lights
27. AS1049 card for third-party traffic signs
77Zinc-coated internal mechanical parts 28. Acoustic alarm 100 dB (±5) - fixed inside
77Complete body (housing, base plate, cover and doors): 29. Aluminium traffic sign (Ø 300mm)
30. LED flashing light on cover for arm movement signalisation
zinc dusting + epoxy structured 31. Anti vandalism LEDs on hood
Total thickness of the surface treatment exceeds 160 μm 32. Non standard RAL colour
33. Treatment for aggressive saline environment.
WORKS TO BE SUPPLIED
BY THE CUSTOMER (Recommended when the barrier is installed within 10km of the
coast and may be subject to salt attack): sandblasting + Alu Zinc
77Adapted ground fastening plating 80μm outside (40μm inside) + polyzinc 80μm + 80μm
77Power supply
77Wiring towards eventual external peripherals powder paint)
34. Raised base
Note: comply with the installation plan (CH6943-GB). 35. 120 VAC - 60 Hz power supply
36. Thermostatic 250 or 500W heating for operation to -25 or
STANDARD DIMENSIONS (MM)
-45°C
Note : for restrictions on the options, consult the rate table.
2000 - 6000 (L)