Page 62 - Vehicle Products Catalogue EN 012019
P. 62

STANDARD TECHNICAL                                                           OPTIONS
SPECIFICATIONS
                                                                             1.	Rigid aluminium skirt
Electrical power supply  Single-phase 230 VAC - 50/60Hz +                    2.	Arm offset on right-hand or left-hand side
                         ground (not to be connected to a floating net-      3.	Automatic opening of the arm in case of power failure
                         work or to an industrial distribution network with  4.	Double stretcher in electro-galvanized steel to prevent
                         a high impedance earth)
                                                                                deformation of the large arms remaining in opened position at rest
Consumption              450W                                                5.	Locking the arm in opened and/or closed position. The reaction in

Motor                    Three-phased asynchronous 250W                         case of power cut (locked or not) must be specified when ordering
                                                                             6.	Double limit switches for information on the arm status in the
Reversible ring and pinion speed reducer, service factor 1.2
                                                                                event of power failure
Useful arm length (L)    6 to 12m; in increments of 0.5m                     7.	Tip support: fixed height tip, adjustable tip, electro-magnetic tip,

Operation not hampered by 120km/h winds                                         anti-vandalism tip, anti-vandalism + electro-magnetic tip, folding
                                                                                tip and electrically lockable tip
Ambient operating        Between -20 and +50°C (without optional             8.	Support leg for fence and aluminium skirt (if no tip support)
temperature              heating)                                            9.	Rotating base with breaker pin in case of impact and report of
                                                                                housing position by dry contact
Tolerated relative       95% without condensation                            10.	 Anti-vandalism belt, protection of the doors and hood
humidity                                                                     11.	 Hood and door intrusion information (by dry contact)
                                                                             12.	 Push-button box
Minimum opening/         3.5 s (adjustable through the control board)        13.	 Fireman emergency opening - anti-vandalism
closing time                                                                 14.	 Programmable clock (weekly or yearly)
                                                                             15.	 Lockable switch on housing
Net weight               230kg                                               16.	 Radio transmitter/receiver
(without arm)                                                                17.	 Detection loop
                                                                             18.	 Presence detector for inductive loops
Weight of the arm        20 to 30kg, depending on length and without         19.	 Photoelectric cell for opening, closing or automatically stopping
                         options
                                                                                  the barrier arm
MCBF (Mean Cycle         In compliance with recommended mainte-              20.	 Cell support post
Between Failure)         nance: 3,000,000 cycles                             21.	 Fixating of the cell
                                                                             22.	 Electronic board for input/output CAN
IP 44                                                                        23.	 Totaling counter with reset button
                                                                             24.	 Leds on arm
                         EC compliant                                        25.	 Traffic lights (Leds) - alone or fixed on barrier
                                                                             26.	 Support post for traffic lights
SURFACE TREATMENTS                                                           27.	 AS1049 card for third-party traffic signs
                                                                             28.	 Acoustic alarm 100 dB (±5) - fixed inside
77Zinc-coated internal mechanical parts                                      29.	 Aluminium traffic sign (Ø 300mm)
77Complete body (housing, base plate, cover and doors): zinc                 30.	 LED flashing light on cover for arm movement signalisation
                                                                             31.	 Anti vandalism Leds on hood
  dusting + epoxy structured                                                 32.	 Non standard RAL colour
  Total thickness of the surface treatment exceeds 160 μm                    33.	 Treatment for aggressive saline environment. (recommended

WORKS TO BE SUPPLIED                                                              when the barrier is installed within 10km of the coast and may
BY THE CUSTOMER                                                                   be subject to salt attack): sandblasting + Alu Zinc plating 80μm
                                                                                  outside (40μm inside) + polyzinc 80μm + 80μm powder paint)
77Adapted ground fastening                                                   34.	 Raised base
77Power supply                                                               35.	 120 VAC - 60 Hz power supply
77Wiring towards eventual external peripherals                               36.	 Thermostatic 250 or 500W heating for operation to -25 or -45°C

Note: comply with the installation plan (CH6943-GB).                         Note : for restrictions on the options, consult the rate table.

STANDARD DIMENSIONS (MM)

                          6000 - 12000 (L)

                                                                                                                                                           = 498 =

                                                                  948
                                                                       1224,5

                                                                                                                                                                   = 498 =
                                                                                                                                                                        = 654 =

                                                                                                                              L + 200 mm