Page 62 - Vehicle Products Catalogue EN 012019
P. 62
STANDARD TECHNICAL OPTIONS
SPECIFICATIONS
1. Rigid aluminium skirt
Electrical power supply Single-phase 230 VAC - 50/60Hz + 2. Arm offset on right-hand or left-hand side
ground (not to be connected to a floating net- 3. Automatic opening of the arm in case of power failure
work or to an industrial distribution network with 4. Double stretcher in electro-galvanized steel to prevent
a high impedance earth)
deformation of the large arms remaining in opened position at rest
Consumption 450W 5. Locking the arm in opened and/or closed position. The reaction in
Motor Three-phased asynchronous 250W case of power cut (locked or not) must be specified when ordering
6. Double limit switches for information on the arm status in the
Reversible ring and pinion speed reducer, service factor 1.2
event of power failure
Useful arm length (L) 6 to 12m; in increments of 0.5m 7. Tip support: fixed height tip, adjustable tip, electro-magnetic tip,
Operation not hampered by 120km/h winds anti-vandalism tip, anti-vandalism + electro-magnetic tip, folding
tip and electrically lockable tip
Ambient operating Between -20 and +50°C (without optional 8. Support leg for fence and aluminium skirt (if no tip support)
temperature heating) 9. Rotating base with breaker pin in case of impact and report of
housing position by dry contact
Tolerated relative 95% without condensation 10. Anti-vandalism belt, protection of the doors and hood
humidity 11. Hood and door intrusion information (by dry contact)
12. Push-button box
Minimum opening/ 3.5 s (adjustable through the control board) 13. Fireman emergency opening - anti-vandalism
closing time 14. Programmable clock (weekly or yearly)
15. Lockable switch on housing
Net weight 230kg 16. Radio transmitter/receiver
(without arm) 17. Detection loop
18. Presence detector for inductive loops
Weight of the arm 20 to 30kg, depending on length and without 19. Photoelectric cell for opening, closing or automatically stopping
options
the barrier arm
MCBF (Mean Cycle In compliance with recommended mainte- 20. Cell support post
Between Failure) nance: 3,000,000 cycles 21. Fixating of the cell
22. Electronic board for input/output CAN
IP 44 23. Totaling counter with reset button
24. Leds on arm
EC compliant 25. Traffic lights (Leds) - alone or fixed on barrier
26. Support post for traffic lights
SURFACE TREATMENTS 27. AS1049 card for third-party traffic signs
28. Acoustic alarm 100 dB (±5) - fixed inside
77Zinc-coated internal mechanical parts 29. Aluminium traffic sign (Ø 300mm)
77Complete body (housing, base plate, cover and doors): zinc 30. LED flashing light on cover for arm movement signalisation
31. Anti vandalism Leds on hood
dusting + epoxy structured 32. Non standard RAL colour
Total thickness of the surface treatment exceeds 160 μm 33. Treatment for aggressive saline environment. (recommended
WORKS TO BE SUPPLIED when the barrier is installed within 10km of the coast and may
BY THE CUSTOMER be subject to salt attack): sandblasting + Alu Zinc plating 80μm
outside (40μm inside) + polyzinc 80μm + 80μm powder paint)
77Adapted ground fastening 34. Raised base
77Power supply 35. 120 VAC - 60 Hz power supply
77Wiring towards eventual external peripherals 36. Thermostatic 250 or 500W heating for operation to -25 or -45°C
Note: comply with the installation plan (CH6943-GB). Note : for restrictions on the options, consult the rate table.
STANDARD DIMENSIONS (MM)
6000 - 12000 (L)
= 498 =
948
1224,5
= 498 =
= 654 =
L + 200 mm
With a constant view of adopting the latest technological developments, Automatic Systems reserves the right to amend the information above, at any time.
Products Catalogue | Vehicle | 62