Page 64 - Vehicle Products Catalogue EN 012019
P. 64

STANDARD TECHNICAL                                                          OPTIONS
SPECIFICATIONS
                                                                            1.	Double stretcher - over and under the arm
Electrical power supply  Single-phase 230 VAC - 50/60Hz (not to be          2.	Locking of the arm in open position
                         connected to a floating network or
                         to an industrial distribution network with a high     The desired reaction in case of power cut (locked or not) must be
                         impedance earth)                                      specified when ordering
                                                                            3.	Double limit switches by dry contacts for information on barrier
Nominal Power            450W                                                  status in the event of power failure
                                                                            4.	Articulated tip support
Motor                    Three-phased asynchronous 250W                     5.	Hood and door intrusion information (by dry contact)
                                                                            6.	Push-button switch box(es) for opening, closing or locking the
Reversible ring and pinion speed reducer                                       arm
                                                                            7.	Emergency services box with key switch (French Standard) for
Useful arm length (L)    Round aluminium arm (BL 45A), length 6 to             opening, closing or locking the arm
                         12m by 1m multiples, made up of 2 or 3 seg-        8.	Detection loop
                         ments fitting into each other of a diameter of     9.	Presence detector for inductive loops
                         100 - 90 - 84mm and which may be guyed by          10.	 Two orange LED R2 (24 VDC) signal lights, Ø180mm, on the arm
                         galvanized steel cables (depending on length       11.	 Red LED R24 (220 VAC) signal light, Ø300mm - alone or fixed

                         or options)                                             on a post on housing
                                                                            12.	 Acoustic alarm 98 dB ±5 (Ø 198), fixed outside - G2 type
                         OR                                                 13.	 NO ENTRY sign 450mm diameter, aluminium and class 2 (see*
                         Rectangular glass fibre arm (BL 45F), 145 x
                         85mm, in 2 segments 6 to 10m in length by 1m            previous page)
                         multiples                                          14.	 Paint of another RAL colour
                                                                            15.	 Treatment for harsh saline environments (recommended
Operation not hampered by 120km/h winds
                                                                                 particularly when the barrier is installed within 10km of the coast and
Ambient operating        Between -25 and +60°C (without optional                 may be subject to salt attack): sandblasting + Alu Zinc plating 40 μm
temperature              heating)                                                inside/80μm outside + polyzinc 80 μm + 80 μm powder paint
                                                                            16.	 Thermostatic 500W heating for operation down to -45°C
Tolerated relative       95% without condensation
humidity                                                                    Note : for restrictions on the options, consult the rate table.

Minimum opening/         3.5 to 8s (adjustable through the control board)   WORKS TO BE SUPPLIED
closing time                                                                BY THE CUSTOMER

Net weight (without      250kg                                              77Ground installation
arm)                                                                        77Power supply
                                                                            77Wiring to any external devices
MCBF (Mean Cycle         In compliance with recommended mainte-
Between Failure)         nance: 3,000,000 cycles                            Note: comply with the installation plan (CH6943-GB)

IP 44

                         CE compliant

SURFACE TREATMENTS

77Zinc-coated internal mechanical parts
77Complete body (housing, base plate, cover and doors): zinc

  dusting + epoxy structured paint
77Total thickness of the surface treatment exceeds 160 μm

STANDARD DIMENSIONS (MM)

BL 45A - ROUND ALUMINIUM ARM                      BL 45F - RECTANGULAR GLASS             BL 45T - FRUSTOCONICAL FIBRE
                                                  FIBRE ARM                              GLASS ARM

       1220                         6 m ... 12 m                                         1220                                  Useful lenght of 12 meters max.
          948       709                                                                       948                              for frustoconical fiber glass arm.

                                                   1220                     6m ... 10 m                            Ø 800: Free area for barrier arm rotation.
                                                      948                                          Subject to all optional equipment (Traffic light, electrical box, ...)
       71                                                                                71

                                                   71

       680                                         741                                   741
          498                                         498                                   498

               498                                         498                                     498
                   954                                        1039                                        1129

With a constant view of adopting the latest technological developments, Automatic Systems reserves the right to amend the information above, at any time.

Products Catalogue | Vehicle | 64
   59   60   61   62   63   64   65   66   67   68   69