STANDARD TECHNICAL OPTIONS
SPECIFICATIONS
1. Double stretcher - over and under the arm
Electrical power supply Single-phase 230 VAC - 50/60Hz (not to be 2. Locking of the arm in open position
connected to a floating network or
to an industrial distribution network with a high The desired reaction in case of power cut (locked or not) must be
impedance earth) specified when ordering
3. Double limit switches by dry contacts for information on barrier
Nominal Power 450W status in the event of power failure
4. Articulated tip support
Motor Three-phased asynchronous 250W 5. Hood and door intrusion information (by dry contact)
6. Push-button switch box(es) for opening, closing or locking the
Reversible ring and pinion speed reducer arm
7. Emergency services box with key switch (French Standard) for
Useful arm length (L) Round aluminium arm (BL 45A), length 6 to opening, closing or locking the arm
12m by 1m multiples, made up of 2 or 3 seg- 8. Detection loop
ments fitting into each other of a diameter of 9. Presence detector for inductive loops
100 - 90 - 84mm and which may be guyed by 10. Two orange LED R2 (24 VDC) signal lights, Ø180mm, on the arm
galvanized steel cables (depending on length 11. Red LED R24 (220 VAC) signal light, Ø300mm - alone or fixed
or options) on a post on housing
12. Acoustic alarm 98 dB ±5 (Ø 198), fixed outside - G2 type
OR 13. NO ENTRY sign 450mm diameter, aluminium and class 2 (see*
Rectangular glass fibre arm (BL 45F), 145 x
85mm, in 2 segments 6 to 10m in length by 1m previous page)
multiples 14. Paint of another RAL colour
15. Treatment for harsh saline environments (recommended
Operation not hampered by 120km/h winds
particularly when the barrier is installed within 10km of the coast and
Ambient operating Between -25 and +60°C (without optional may be subject to salt attack): sandblasting + Alu Zinc plating 40 μm
temperature heating) inside/80μm outside + polyzinc 80 μm + 80 μm powder paint
16. Thermostatic 500W heating for operation down to -45°C
Tolerated relative 95% without condensation
humidity Note : for restrictions on the options, consult the rate table.
Minimum opening/ 3.5 to 8s (adjustable through the control board) WORKS TO BE SUPPLIED
closing time BY THE CUSTOMER
Net weight (without 250kg 77Ground installation
arm) 77Power supply
77Wiring to any external devices
MCBF (Mean Cycle In compliance with recommended mainte-
Between Failure) nance: 3,000,000 cycles Note: comply with the installation plan (CH6943-GB)
IP 44
CE compliant
SURFACE TREATMENTS
77Zinc-coated internal mechanical parts
77Complete body (housing, base plate, cover and doors): zinc
dusting + epoxy structured paint
77Total thickness of the surface treatment exceeds 160 μm
STANDARD DIMENSIONS (MM)
BL 45A - ROUND ALUMINIUM ARM BL 45F - RECTANGULAR GLASS BL 45T - FRUSTOCONICAL FIBRE
FIBRE ARM GLASS ARM
1220 6 m ... 12 m 1220 Useful lenght of 12 meters max.
948 709 948 for frustoconical fiber glass arm.
1220 6m ... 10 m Ø 800: Free area for barrier arm rotation.
948 Subject to all optional equipment (Traffic light, electrical box, ...)
71 71
71
680 741 741
498 498 498
498 498 498
954 1039 1129
With a constant view of adopting the latest technological developments, Automatic Systems reserves the right to amend the information above, at any time.